Moyer Diebel MD1000HT User Manual

Page 19

Advertising
background image

13

________________ Installation Guide

;

Chemical Dispensers MD-1000HT

MD-1000HT • Chemical Dispensers

13. Now you must connect your pumps to

the dishwasher neutral return. All white
wires marked with No. 2 are neutral wires;
however, you are not authorized to connect
to any #2 wire that you may identify.

14. Run a 12 gauge white wire with spade terminal connector (not supplied) from your

chemical dispensing pumps to the neutral #2 white wire located on the main power
transformer in the control cabinet.

A

A

A

A

ATTENTION

TTENTION

TTENTION

TTENTION

TTENTION INST

INST

INST

INST

INSTALLER

ALLER

ALLER

ALLER

ALLER

DO NOT TURN ON the dishwasher power switch

located on the front of the top-mounted control cabinet

before the Initial Start-up is completed

Powering the dishwasher as described above, without knowing for

certain that the Initial Start-up was performed, may make you liable for any damages

stemming from your actions.

Note:
You may void the dishwasher warranty if you connect the neutral wire
of your dispensing system anywhere else than at the main power
transformer.

Caution:
The NEUTRAL RETURN (#2 white wires) and Chassis Ground are
not the same point electrically. Improper wiring to these points may
result in unusual voltage readings and damage to the dishwasher's
electrical circuits.STOP WORKING ON THE DISHWASHER AT ONCE,
if you do not know the difference between a neutral return and chassis
ground.