The Troubleshooter

In order to find the cause of a breakdown or abnormal operating condition in your dishwasher please

ensure that:

1. All switches are ON
2. Drain overflow tube is in place and seated
3. Wash pipe and rinse nozzles are clean
4. Spray arms are in their proper positions
5. Round screen is properly positioned
6. Detergent, sanitizer and rinse additive dispensers are adequately filled
8. Doors are fully closed.

That wasn't it? Check for a solution below:

PROBLEM

CAUSE

SOLUTION

Cycle will not start

Door not closed ........................... Make sure doors are fully closed
Door safety switch faulty ............. Contact your service agency
Main switch off ............................. Check disconnect

Low or no water

Main water supply is turned off ... Turn on house water supply
Drain/overflow tube is not
in place and seated ..................... Clean, replace and seat drain tube

..................................................... as needed.

Faulty fill valve ............................. Contact your chemcial supplier.

Continuous water filling

Fill valve will not close ................. Clean or replace

Motor not running

Defective contactor ..................... Contact your servicer
Defective motor ........................... Contact your servicer

Wash tank water temperature ..................................................... Incoming water temperature
is low when in use

..................................................... at machine too low
..................................................... Raise temperature to 140°F/60°C

Defective thermometer ................ Check or replace
Defective solenoid valve ............. Check or replace

Arms not rotating

Rinse nozzles not clean .............. Clean
Bearings worn .............................. Replace
Water supply pressure low ......... Check incoming water pressure

Insufficient pumped spray

Clogged intake screen ............... Clean

pressure

Clogged spray pipe ..................... Clean
Low water level in tank ................ Check drain and overflow tube, timer may

..................................................... need adjustment, contact servicer

Defective pump seal .................... Contact service agent

Insufficient rinse or no

Faulty pressure regulating valve . Clean or replace

rinse

Improper setting on pressure
regulating valve ........................... Set static pressure to 35 psi
Clogged rinse nozzle and/or
pipe .............................................. Clean with paper clip/delime
Improper water line size .............. Have installer change to proper size 3/4" NPT