31

_____________ Installation Guide

;

Drain Connection MD-1000LT

1. Locate the dishwasher drain connection underneath the machine frame.

2. Install a drain line conforming to local plumbing and health regulations.

Drain: 1-7/8" stainless steel, slip-fit hose connection

Max flow: 15 Us gal/min. (13.5 Imperial gal/min) 57liters/min.

1. The factory has no requirements for vent hoods; but, local codes and regulations in your

area supersede our suggestions. Consult your local building and health authorities for
local requirements.

2. Dishroom ventilation must provide sufficient airflow to prevent excessive humidity in the

work area. 200-400cfm/5.6- 11.3 k Liters/min - is sufficient.

3. The dishwasher must not be subjected to continual drafts or cold air.

;

Ventilation MD-1000LT

MD-1000LT • Drain Connection