CHAPTER 3: CONNECTING THE GALILEO 616

24

CONNECTING THE SIM-3022 ANALYZER

The rear panel of the Galileo 616 includes a connector for direct connection to the SIM-3022
Audio Analyzer. Once connected, the Galileo 616 can act as a line switcher for the analyzer.
SIM 3 users can measure across any selection of inputs and outputs without any additional
patching beyond the single cable connection to the analyzer.

The default bus address for the Galileo is 10, and the available range is 10 through 14 so that
multiple Galileo units may be connected and measured. When the analyzer is connected, it
will be auto-detected by Galileo, and its presence will be noted in the SIM 3 Settings section
of the System Settings window in the Compass control software, and by the SIM 3 LED on the
Galileo front panel.

NOTE:

Within SIM 3, addresses 0 through 9 are reserved for the SIM-3088 line switcher

units.