CHAPTER 4: USING THE GALILEO FRONT PANEL

34

Input Range and Output Range

Select Input Range or Output Range from the System Settings page to set the voltage range
at either +20 dBu or +26 dBu. Apply the settings globally by highlighting “Set All Voltage
Ranges to +20 dBu” (or +26 dBu) and pressing the Enter button.

Adjust the individual input or output voltage range for each channel by scrolling to the desired
channel using the Up and Down arrows, and then pressing or turning the Blue knob to toggle
between the two values.

NOTE:

The adjustable output range provides two level output settings to drive

Meyer Sound self-powered products. The +20 dBu output range setting lowers

the overall noise floor by nearly 6 dB. However, this setting makes the Galileo output
signal more vulnerable to defects in the overall grounding system. Thus the actual
improvement attained depends on the quality of the grounding between components.
For this reason, the default setting is +26 dBu. In either setting, the digital gain will
compensate for either analog output gain so that the overall system output level set in
Galileo will remain the same.

Input Voltage Range Page