EMC Emissions

Emissions

Approved according to:

US - FCC Part 15 sub part J, class A

Europe - EN55022 class A

Immunity

Approved according to:

EN 50082-1

Interfaces

24 x 10/100BASE-T ports with RJ-45 connectors.

RS-232 for terminal setup, RJ-45 connector on front panel.

RS-232 SLIP for modem connection, 9-pin D-type connector on back panel.

Standards Compliance

The Cajun P120 complies with:

IEEE 802.3x

Flow Control

IEEE 802.1Q

VLAN Standard (Tagging and priority)

IEEE 8021.D

Spanning Tree protocol

IEEE 803.3z

Gigabit Ethernet ports

MTBF

Table 7.3

Mean Time Between Failure (MTBF) for all Cajun P120 Configurations

MTBF in Hours

MTBF in Hours (P120

Main Board + Expansion

Sub-module)

P120 Main Board only

143,432

Not Applicable

X120S2

345,303 (only X120S2)

101,338

X120L2

345,303 (only X120L2)

101,338

X120S1

677,158 (only X120S1)

118,361

X120L1

677,158 (only X120L1)

118,361

X120F2

864,068 (only X120F2)

123,012

X120T8

1,315,846 (only X120T8)

129,334