109

Chapter 6 - Detailed Description of Functions

6-4. Detailed Description of the Menus

[I/O] Submenu

INPUT

Saved

Yes

Setting

PARA, SERI, AUTO

Default

AUTO

This selects the connector for connection to a computer. Commands from the computer are received via the connector you specify
here. When this is set to [AUTO], the connector through which commands are first received after powerup is enabled automati-
cally.
When this is set to [SERI] or [AUTO], the menu for setting the serial communication parameters appears.

STOP

Saved

Yes

Setting

1, 2

Default

1

This makes the setting for the number of stop bits, one of the serial communication parameters. This is displayed only when
[INPUT] is set to [SERI] or [AUTO].

DATA

Saved

Yes

Setting

7, 8

Default

8

This makes the setting for the data bit length, one of the serial communication parameters. This is displayed only when [INPUT]
is set to [SERI] or [AUTO].

PARITY

Saved

Yes

Setting

NONE, ODD, EVEN

Default

NONE

This makes the setting for parity, one of the serial communication parameters. This is displayed only when [INPUT] is set to
[SERI] or [AUTO].

BAUDRATE

Saved

Yes

Setting

4800, 9600, 19200, 38400

Default

9600

This makes the setting for the baud rate, one of the serial communication parameters. This is displayed only when [INPUT] is set
to [SERI] or [AUTO].

HANDSHAKE

Saved

Yes

Setting

HARD, XON/OFF

Default

HARD

This makes the setting for handshaking (flow control), one of the serial communication parameters. [HARD] indicates hardware
handshaking, and [XON/OFF] indicates XON/XOFF handshaking. This is displayed only when [INPUT] is set to [SERI] or
[AUTO].