39

Chapter 3 - Preparations

3-2. Cutter Installation Method 1 (With Nose Unit)

2. Nose-unit Installation and Menu Settings

5

Install the nose unit. Tighten fully, then loosen
two turns.

6

Fully loosen the lock nut.

7

Use the menus to set [AUTO Z CONTROL] to ON.

(1) Press

several times to display the screen shown at right.

(2) Press

to move the blinking cursor to [OTHERS], then press

.

(3) Press

several times to display the screen shown at right.

(4) Press

to move the blinking cursor to [ON], then press

.

8

Use the menu to set [REVOLUTION] to ON.

(1) Press

several times to display the screen shown at right.

(2) Press

to move the blinking cursor to [OTHERS], then press

.

(3) Press

to move the blinking cursor to [ON], then press

.

9

Press

several times to return to the top screen.

Be sure to loosen the lock nut.

X 0 Y 0
Z 0 8000RPM

I/O

O

THERS

TEACHING SELF

REVOLUTION
<ON> OFF