Maintenance of the z-axis screw – IBM EGX-400 User Manual

Page 125

Advertising
background image

121

Chapter 7 - Maintenance

7-2. Maintenance and Inspection

Maintenance of the Z-axis Screw

Use a cleaning cloth or the like to clean away any buildup of cutting waste or old grease on the Z-axis screw, then apply
a small amount of fresh grease.

Recommended grease: Lithium grease #2 or the equivalent

Switch off the machine and unplug the power cord from the electrical outlet before performing cleaning
or maintenance.
Failure to do so may result in injury or electrical shock.

Do not lubricate any areas other than
the Z-axis screw.

Advertising