5. list of supported commands, Rml-1 commands – IBM EGX-400 User Manual

Page 142

Advertising
background image

138

Chapter 9 - Appendix

9-5. List of Supported Commands

RML-1 Commands

Mode 1

Mode 2

Command

Format

Parameter

Range [Default]

@

Input Z1 & Z2

@ Z1, Z2

Z1

Position on Z1

-4250 to 0 [0]

Z2

Position on Z2

0 to 4250 [0]

H

Home

H

None

D

Draw

D x1, y1, x2, y2, ..... , xn, yn

xn, yn

Absolute coordinate

*1

M

Move

M x1, y1, x2, y2, ..... , xn, yn

xn, yn

Absolute coordinate

*1

I

Relative Draw

I x1, y1, x2, y2, ..... ,

xn, yn

Relative coordinate

*1

xn, yn

R

Relative Move

R x1, y1, x2, y2, ..... ,

xn, yn

Relative coordinate

*1

xn, yn

V

Velocity Z-axis

V f

f

Feed rate for Z axis

0 to 50 [mm/sec] [2 [mm/sec]]

F

Velocity X,Y-axis

F f

f

Feed rate for X and Y axis

0 to 100 [mm/sec] [2 [mm/sec]]

Z

XYZ-axis

Z x1, y1, z1, ..... , xn, yn, zn

xn, yn

XY coordinate

*1

Simultaneous Feed

Z x1, y1, z1, ..... , xn, yn, zn

zn

Z coordinate

*1

W

Dwell

W t

t

Dwell time

0 to 32767 [msec] [0 [msec]]

^

Call mode2

^ [mode2] [parameter].....

[parameter] [;]

Command

Format

Parameter

Range [Default]

DF Default

DF;

None

IN

Initialize

IN;

None

PA

Plot Absolute

PA x1, y1 (,x2, y2, ..... , xn, yn);

xn, yn

Absolute XY coordinate

*1

PA;

PD Pen Down

PD x1, y1 (,x2, y2, ..... , xn, yn);

xn, yn

XY coordinate

*1

PD;

PR

Plot Relative

PR x1, y1 (, x2, y2, ..... ,

xn, yn

Relative XY coordinate

*1

xn, yn);

PR;

PU Pen Up

PU x1, y1 (,x2, y2, ..... , xn, yn);

xn, yn

XY coordinate

*1

PU;

VS Velocity select

VS s;

s

Feed rate for X and Y axis

0 to 100 [mm/sec] [2 [mm/sec]]

VS;

* 1 : -(2

23

-1) to +(2

23

-1)

Advertising