Rs-232 terminal product interface specifications – InFocus IN82 User Manual

Page 32

Advertising
background image

31

RS-232 terminal Product Interface specifications

Communication configuration

To control the projector from an LCD control panel, connect an RS-232 cable to
the serial control connector on the projector and set your computer’s serial port
settings to match this communication configuration:

Command format

All commands consist of 3 alpha characters followed by a request, all enclosed in
“greater than” and “less than” signs. The request can be a read request (indicated
by a “?”) or a write request (indicated by 1 to 4 ASCII digits).

A read request format: <AAA?> where

<

starts the command

AAA

denotes the command

?

denotes the read request

>

ends the command

A write request example: <AAA=####> where

<

starts the command

AAA

denotes the command

=####

denotes the value to be written
(leading zeros not necessary)

>

ends the command

Some commands have ranges, while others are absolute. If a number greater than
the maximum range is received, it is automatically set to the maximum number for
that function. With absolute settings, “0” is off, 1-9999 is on. The one exception is

the Power command, where 0 is off and 1 is on

.

Refer to the support section of our website for detailed information on the Prod-
uct Interface formats.

Setting

Value

Bits per second

115,200

Data bits

8

Parity

None

Stop bits

1

Flow control

None

Emulation

VT100

K1 RG.fm Page 31 Thursday, September 27, 2007 10:24 AM