Siemens MICROMASTER 440 User Manual

Page 12

Advertising
background image

2 Electrical Installation

Issue 10/06

MICROMASTER 440

12

Operating Instructions (Compact)

Input voltage range

3 AC 500 V – 600 V, ± 10 %

(Unfiltered)

Order No.

6SE6440- 2UE17-

5CA1

2UE21-

5CA1

2UE22-

2CA1

2UE24-

0CA1

2UE25-

5CA1

2UE27-

5CA1

2UE31-

1CA1

2UE31-

5DA1

Frame Size

C D

[kW]

0,75 1,5 2,2 4,0

5,5 7,5 11,0 15,0

Output Rating(CT)

[hp]

1,0 2,0 3,0 5,0 7,5 10,0 15,0 20,0

Output Power

[kVA]

1,3 2,6 3,7 5,8 8,6 10,5 16,2 21,0

CT-Input Current 1)

[A]

2,0 3,7 5,3 8,1 11,1 14,4 21,5 24,9

CT-Output Current

[A]

1,4 2,7 3,9 6,1 9,0 11,0 17,0 22,0

VT-Input Current 1)

[A]

3,2 4,4 6,9 9,4 12,6 18,1 24,9 30,0

VT-Output Current

[A]

2,7 3,9 6,1 9,0 11,0 17,0 22,0 27,0

Fuse [A]

10 10 10 16 16 25 32 35

Recommended 3NA

3803-6 3803-6 3803-6 3805-6 3805-6 3810-6 3812-6 3814-6

For UL specified

3NE

*

*

*

*

*

*

*

1803-0

[mm

2

]

1,0 1,0 1,0 1,5 1,5 2,5 4,0 6,0

Input Cable, min.

[AWG]

18 18 18 16 16 14 12 10

[mm

2

]

10,0 10,0 10,0 10,0 10,0 10,0 10,0 35,0

Input Cable, max.

[AWG]

8 8 8 8 8 8 8 2

[mm

2

]

1,0 1,0 1,0 1,0 1,0 2,5 4,0 4,0

Output Cable, min.

[AWG]

18 18 18 18 18 14 12 12

[mm

2

]

10,0 10,0 10,0 10,0 10,0 10,0 10,0 35,0

Output Cable, max.

[AWG]

8 8 8 8 8 8 8 2

[kg]

5,5 5,5 5,5 5,5 5,5 5,5 5,5 16,0

Weight

[lbs]

12,1 12,1 12,1 12,1 12,1 12,1 12,1 35,0

[Nm]

2,25 10

Tightening torques for
power terminals

[lbf.in]

(20) (89)

Order No.

6SE6440- 2UE31-

8DA1

2UE32-

2DA1

2UE33-

0EA1

2UE33-

7EA1

2UE34-

5FA1

2UE35-

5FA1

2UE37-

5FA1

Frame Size

D E

F

[kW]

18,5 22,0 30,0 37,0 45,0 55,0 75,0

Output Rating(CT)

[hp]

25,0 30,0 40,0 50,0 60,0 75,0 100,0

Output Power

[kVA]

25,7 30,5 39,1 49,5 59,1 73,4 94,3

CT-Input Current 1)

[A]

30,0 35,0 48,0 58,0 69,0 83,0 113,0

CT-Output Current

[A]

27,0 32,0 41,0 52,0 62,0 77,0 99,0

VT-Input Current 1)

[A]

35,0 48,0 58,0 69,0 83,0 113,0

138,0

VT-Output Current

[A]

32,0 41,0 52,0 62,0 77,0 99,0 125,0

Fuse [A]

50 63 80 80 125 160

160

Recommended 3NA

3820-6 3822-6 3824-6 3824-6 3132-6 3136-6 3136-6

For UL specified

3NE

1817-0 1818-0 1820-0 1820-0 1022-0 1224-0 1224-0

[mm

2

]

10,0 10,0 16,0 25,0 25,0 50,0 50,0

Input Cable, min.

[AWG]

8 8 6 3 3 1/0

1/0

[mm

2

]

35,0 35,0 35,0 35,0 150,0 150,0

150,0

Input Cable, max.

[AWG]

2 2 2 2 300

300

300

[mm

2

]

6,0 10,0 16,0 16,0 25,0 35,0 50,0

Output Cable, min.

[AWG]

10 8 6 6 3 2 1/0

[mm

2

]

35,0 35,0 35,0 35,0 150,0 150,0

150,0

Output Cable, max.

[AWG]

2 2 2 2 300

300

300

[kg]

16,0 16,0 20,0 20,0 56,0 56,0 56,0

Weight

[lbs]

35,0 35,0 44,0 44,0 123,0 123,0

123,0

[Nm]

10 50

Tightening torques for
power terminals

[lbf.in]

(89) (445)

1) Secondary conditions: Input current at the rated operating point - applies for the short-circuit voltage of the line

supply V

k

= 2 % referred to the rated drive converter power and a rated line supply voltage

of 500 V without line commutating reactor.

* UL listed fuses such as Class NON from Bussmann are required for use in America