Operating Instructions (Compact)

6.4.18.4 DC

brake

BI: Enabling the DC brake
This enables DC braking using a signal that was used from an external source. The
function remains active as long as the external input signal is active. DC braking causes
the motor to quickly stop by injecting a DC current

⏐f⏐

P0347

f*

i

t

t

t

1

0

f_act

DC braking

0

1

DC braking active

r0053

Bit00

t

f_set

(0:0)

P1230.C

BI: Enable DC brk.

Note: DC brake can be applied in drive states r0002 = 1, 4, 5

DC braking current

(entered in %)

Defines level of DC current in [%] relative to rated motor current (P0305).

Duration of DC braking

(entered in s)

Defines duration for which DC injection braking is to be active following an OFF1 or OFF3
command.

t

P1234

OFF1/OFF3

ON

t

t

⏐f⏐

P1233

1

tt

P0347

OFF2

DC braking

OFF2

0

1

DC braking active

r0053

Bit00

P1230 = ...

100 %

0 s

P1232 =...

P1233 =...