Drive data set (dds) – Siemens MICROMASTER 440 User Manual

Page 70

Advertising
background image

6 Commissioning

Issue 10/06

MICROMASTER 440

70

Operating Instructions (Compact)

Drive data set (DDS)

Drive data set (DDS) bit 0
Selects the command source from which bit 0 should be read-out to select a drive data set.

t

0

1

2

3

(0:0)

BI: DDS bit 0

P0820

(0:0)

BI: DDS bit 1

P0821

t

0

1

2

3

CO/BO: Act CtrlWd2

r0055

r0055

CO/BO: Act CtrlWd2

r0055

r0055

.04

.04

.05

.05

r0051[1]

Active DDS

Select DDS

approx. 50 ms

approx. 50 ms

Changeover time

Changeover time

Operation

Ready

t

r0051 [2]

CO: Active DDS

.01

The currently active drive data set (DDS) is displayed using parameter r0051[1].

BI: DDS bit 1
Selects command source from which Bit 1 for selecting a drive data set is to be read in
(see parameter P0820).

0

P0820 = ...

0:0

P0821 = ...

Advertising