2 Electrical Installation

MICROMASTER 440
Operating Instructions (Compact)

21

2.3 Control

terminals

Terminal Designation Function

1

Output +10 V

2

Output 0 V

3

ADC1+

Analog input 1 (+)

4

ADC1–

Analog input 1 (–)

5

DIN1

Digital input 1

6

DIN2

Digital input 2

7

DIN3

Digital input 3

8

DIN4

Digital input 4

9

Isolated output +24 V / max. 100 mA

10

ADC2+

Analog input 2 (+)

11

ADC2–

Analog input 2 (–)

12

DAC1+

Analog output 1 (+)

13

DAC1–

Analog output 1 (–)

14

PTCA

Connection for PTC / KTY84

15

PTCB

Connection for PTC / KTY84

16

DIN5

Digital input 5

17

DIN6

Digital input 6

18

DOUT1/NC

Digital output 1 / NC contact

19

DOUT1/NO

Digital output 1 / NO contact

20

DOUT1/COM

Digital output 1 / Changeover contact

21

DOUT2/NO

Digital output 2 / NO contact

22

DOUT2/COM

Digital output 2 / Changeover contact

23

DOUT3/NC

Digital output 3 / NC contact

24

DOUT3/NO

Digital output 3 / NO contact

25

DOUT3/COM

Digital output 3 / Changeover contact

26

DAC2+

Analog output 2 (+)

27

DAC2–

Analog output 2 (–)

28

Isolated output 0 V / max. 100 mA

29 P+

RS485

port

30 N–

RS485

port

Fig. 2-9

Control terminals of MICROMASTER 440