17 field-orientated control, Limitations – Siemens MICROMASTER 440 User Manual

Page 50

Advertising
background image

6 Commissioning

Issue 10/06

MICROMASTER 440

50

Operating Instructions (Compact)

6.4.17 Field-orientated

control

Limitations

To avoid a premature limitation the limits of the torque (P1520, P1521) and power
(P1530, P1531) should be set to the maximum value, if the application allows it.

Motor overload factor [%]
Defines motor overload current limit in [%] relative to p0305 (rated motor current). Limited to
maximum inverter current or to 400 % of rated motor current (p0305), whichever is the
lower.

100

p0305

p0305)

4

(r0209,

min

p0640

max

=

CO: Upper torque limit

Specifies fixed value for upper
torque limitation.

P1520

max

P1520

def

r0333

1.5

=

r0333

4

±

=

CO: Lower torque limit

Enters fixed value of lower
torque limitation.

P1521

max

P1521

def

r0333

1.5

=

r0333

4

±

=

f

1

~

Torque limitation

Resultant

torque limit

Power

limitation

|f

act

r1526
r1527

Stall

limitation

p1530
p1531

f

1

~

2

Constant

torque

f

stall

Constant

power

|

|M|

Stall

power

Motoring power limitation

Defines fixed value for the max. permissible
motoring active power.

P1530

def

P1530

max

0307

P

3

=

0307

P

5

.

2

=

Regenerative power limitation

Enters fixed value for the max. permissible
regenerative active power

P1531

max

P0307

3

-

=

P1531

def

P0307

2.5

-

=

M

f

f

2

P

M

π

=

Power limitation (motoring, regenerative)

p1530

p1531

p1530

p1531

p0640 = ...

150.0 %

P1520 = ...

P1521 = ...

P1530 = ...

P1531 = ...

FC-spec.

FC-spec.

FC-spec.

FC-spec.

Advertising