Brakes – Sterling Trucks Acterra MX User Manual

Page 114

Advertising
background image

the

Acterra

®

Workshop Manual for inspection,

troubleshooting, and repair procedures.

4.

Measure the applied chamber stroke. See

Table 3

for the proper stroke for the type of

chamber being used. If the stroke is too short,
the brakes may drag or will not fully apply. Check
for improper operation or adjustment of the auto-
matic slack adjuster. See Group 42 of the
Acterra

®

Workshop Manual for inspection and

troubleshooting procedures.

5.

Start the engine and build air pressure to at least
100 psi (689 kPa). Shut down the engine.

6.

Check all of the foundation brake components for
damage, wear, and loose or missing parts. Re-
pair as needed. See Group 42 of the

Acterra

®

Workshop Manual for repair procedures.

Brake Chamber Stroke Specifications

Chamber

Max Applied Stroke: inch (mm)

Manufacturer

Type

*

Size

Gunite

Standard Stroke

9

1-3/8 (35)

12

16

1-3/4 (44)

20

24

30

2 (51)

36

2-1/4 (57)

Long Stroke

16

2 (51)

20

24 (2-1/2 inch rated

stroke)

24 (3 inch rated

stroke)

2-1/2 (64)

30

Haldex

Standard Stroke

12

1-3/8 (35)

16

1-3/4 (44)

20

24

2-1/2-Inch Extended Stroke

24

2 (51)

3-Inch Extended Stroke

24

2-1/2 (64)

Standard Stroke

30

2 (51)

Long Stroke

30

2-1/2 (64)