Engine cooling/radiator – Sterling Trucks Acterra MX User Manual

Page 47

Advertising
background image

10. Check the fan drive for discoloration or any other

signs of slipping or overheating.

NOTE: The fan clutch may slip if the air supply
pressure is below 70 psi (483 kPa) or if there is
a leak inside the fan clutch. Any leak must be
remedied.

11. Check the fan clutch bearings.

11.1

Turn the fan in both directions and feel
for worn hub bearings.

11.2

If possible, remove the drive belt and
check for worn sheave bearings by turn-
ing the sheave in both directions.

11.3

If either the hub or sheave bearings are
worn, replace them, using a Horton Drive-
Master Super Kit.

For instructions and kit part number, see
Group 20 of the

Acterra

®

Workshop

Manual.

f200581

05/30/2002

Fig. 8, Checking for Air Leaks (Horton DriveMaster)

Engine Cooling/Radiator

20

Acterra Maintenance Manual, January 2007