Error information – Sanyo POA-PN03C User Manual

Page 86

Advertising
background image



Chapter 5 Network Capture

Error messages

Cause and corresponding

Set up the parameter.

Error when executing the communication. The parameter setting

(host name, capture port) has not been set.

Check parameter setting (+p.71)

It has not been registered to PJ

as a group.

Error when executing Start Communication or Start real time cap-

ture. The IP address of the computer has not been registered.

Register the IP address by using the web browser (+p.78)

Cannot be displayed as PJ is

under display.

Error when executing Start Communication or Start real time cap-

ture. The other capture, viewer or advanced card imager function

is now operating.

Wait until the communication function is available.

Cannot connect to PJ.

Cannot establish the connection with the network unit when

executing the Start communication, End communication, Capture

transfer, Start real time capture or End real time capture.

Check connection of the network cable.

Cannot transfer data to PJ.

Cannot transfer the data to the network unit when executing the

Start Communication, End Communication, Capture transfer, Start

real time capture or End real time capture. The time out period is

10 seconds.

Check connection of the network cable.

Cannot receive data from PJ.

Cannot receive the data from the network unit when executing

the Start Communication, End Communication, Capture transfer,

Start real time capture or End real time capture. The time out

period is 10 seconds.

Check connection of the network cable.

Other PC has authority.

Cannot complete "Network

Communication".

When executing the End communication, you cannot quit the

communication because other computer has an authority

Other PC has authority. Cannot

obtain authority.

Other computer has an authority.

The server name or address

could not be resolved.

When setting the parameter, the computer cannot find the set-

ting host name or IP address in the network.

Use available host name or IP address.

Invalid port number

When setting the parameter, the reserved port number is speci-

fied.

Check parameter setting (+p.71)

PJ has not started Network
Communication. Close the window
and open it again.

The projector might have turned off during the communication.

Check projector power and restart executing "Start communica-

tion".

Error information