SMC Networks SMC TigerAccess SMC7824M/FSW User Manual

Page 433

Advertising
background image

SNMP

-

SERVER

HOST

20-7

community command prior to using the snmp-server host
command. (Maximum length: 32 characters)

version - Specifies whether to send notifications as SNMP Version

1, 2c or 3 traps. (Range: 1, 2c, 3; Default: 1)
- auth | noauth | priv - This group uses SNMPv3 with

authentication, no authentication, or with authentication and
privacy. See “Simple Network Management Protocol” on page 5-1
for further information about these authentication and encryption
options.

port - Host UDP port to use. (Range: 1-65535; Default: 162)

Default Setting

Host Address: None
Notification Type: Traps
SNMP Version: 1
UDP Port: 162

Command Mode

Global Configuration

Command Usage

• If you do not enter an snmp-server host command, no notifications

are sent. In order to configure the switch to send SNMP notifications,
you must enter at least one snmp-server host command. In order to
enable multiple hosts, you must issue a separate snmp-server host
command for each host.

• The snmp-server host command is used in conjunction with the

snmp-server enable traps command. Use the snmp-server enable
traps
command to enable the sending of traps or informs and to
specify which SNMP notifications are sent globally. For a host to
receive notifications, at least one snmp-server enable traps
command and the snmp-server host command for that host must be
enabled.

• Some notification types cannot be controlled with the snmp-server

enable traps command. For example, some notification types are
always enabled.

Advertising