Recording, Normal recording, Timer recording – Sanyo DSR-3709 User Manual

Page 24

Advertising
background image

English

23

3

RECORDING

Use the following procedure to record the monitored video

in the normal recording area.

Recording will not be possible until a time has been set for

the digital video recorder. Make sure to set the time.

(JP.17)

1

Press the [REC/STOP] button.

The REC/STOP indicator lights up, “REC” appears on-

screen (i.e., the recording symbol), and recording starts.

z

When recording for the first time, the default settings

are used. For details regarding modification of the

picture quality or recording rate, see P.71.

z

When the space remaining in the normal recording area

drops below a preset value, the FULL indicator on the

digital video recorder’s front panel starts to flash. If

recording is continued beyond this point, the normal

recording area will become full, recording will stop, and

the FULL indicator will stop flashing and remain lit. In

such a case, use the <RECORDING AREA SET>

screen to perform “AREA FULL RESET” for the normal

recording area, thus allowing recording to start again

from the beginning. (JP.67)

z

Playback is possible even while recording. See P.26 for

more details.

2

Press and hold the [REC/STOP] button

for approximately 3 seconds.

“REC” disappears from the operation display and

recording ends.

Use the following procedure to record the monitored video

for a preset length of time in the normal recording area.

Recording will not be possible until a time has been set for

the digital video recorder. Make sure to set the time. (JP.17)

1

Press the [TIMER] button.

The TIMER indicator lights up and the digital video

recorder enters timer recording standby mode.

(1) See P.74 for more details on timer recording settings.

(2) At the time specified for the start of timer recording, the

REC/STOP indicator lights up, “REC” appears on-

screen (i.e., the recording symbol), and recording starts.

(3) At the time specified for the end of timer recording, the

REC/STOP indicator turns off, and recording ends.

The [TIMER] button remains lit up.

z

When the space remaining in the normal recording area

drops below a preset value, the FULL indicator on the

digital video recorder’s front panel starts to flash. If

recording is continued beyond this point, the normal

recording area will become full, recording will stop, and

the FULL indicator will stop flashing and remain lit. In

such a case, use the <RECORDING AREA SET> menu

to perform “AREA FULL RESET” for the normal

recording area, thus allowing recording to start again

from the beginning. (JP.67)

z

Playback is possible even while recording. See P.26 for

more details.

2

Press the [TIMER] button.

The TIMER indicator turns off and recording ends.

CARD

CARD

MENU

RESET

EJECT

[REC/STOP] button

[TIMER] button

FULL indicator

POWER indicator

Normal recording

Ending normal recording

02

0

01-01-04 00:00:00 REC REPEAT EN A ALARM 0000

Recording symbol

REC/STOP

REC/STOP

Timer recording

Stopping timer recording before completion

02

0

01-01-04 00:00:00 REC REPEAT EN A ALARM 0000

TIMER

TIMER

e00_l8hbg_us_7.book Page 23 Thursday, November 25, 2004 1:44 PM