Sanyo DSR-3709 User Manual

Page 85

Advertising
background image

RECORD SET

3

84

English

SE
TTIN

GS

z

The period for “T-1” through “T-4” as set in step 9
changes to that of “TIME PERIOD A” or “TIME PERIOD
B” on P.57.

z

When time period is unset, T-1 settings are enabled
and T-2 through T-4 are disabled.

z

The sensitivity level can be checked using the setting
screen. When motion is detected, the sensor color
changes from green to red, and a buzzer is sounded.
If detection is too sensitive, an alarm can be triggered
even by slight changes in lighting; accordingly, the
sensitivity level should be set to match the camera
location.

1

Press the [MENU] button and turn the
jog dial to select “2. RECORD SET”, and
then turn the shuttle dial.

The <RECORD SET> screen is displayed.

2

Turn the jog dial to select “8. ALARM
OPERATION SET”, and then turn the
shuttle dial clockwise.

The <ALARM OPERATION SET> screen is displayed with
the cursor positioned on “ALARM RETRIGGER”.

3

Turn the shuttle dial clockwise.

“OFF” flashes in the “ALARM RETRIGGER” field.

4

Turn the jog dial to set the alarm trigger
to “ON”, and then turn the shuttle dial
clockwise.

The cursor moves to “MAIN MON. DISPLAY”.

[Settings] (‹ indicates default setting)

1

Turn the jog dial to select “MAIN MON.
DISPLAY”, and then turn the shuttle dial
clockwise.

“NC” starts to flash for “MAIN MON. DISPLAY”.

[Settings] (‹ indicates default setting)

Setting alarm operation and display

MENU

<ALARM OPERATION SET>
ALARM RETRIGGER : OFF

MAIN MON. DISPLAY : NC
ALARM PRIORITY : LAST
MON.2 DISPLAY : OFF

Setting

Description

‹

OFF

Even if a new alarm is received on the same channel
during alarm recording, the duration is not extended.

ON

If a new alarm is received on the same channel during
alarm recording, the duration is extended and both
alarms are treated as one. (Example: Input in the alarm
sequence A

→ C) However, if the new alarm is on a

different channel, the alarms are treated separately.
(Example: Input in the alarm sequence A

→ B → C)

Setting alarm display

Setting

Description

FULL

When an alarm is detected, the video on the
channel containing the alarm is displayed in full
screen format on the main monitor.

9

When an alarm is detected, a multi-9 screen
display is presented on the main monitor.

16

When an alarm is detected, a multi-16 screen
display is presented on the main monitor. (This can
only be set on the DSR-3716.)

‹

NC

The main monitor’s display does not change when
an alarm is detected.

CH1

CH2

Alarm

Alarm

Alarm Recording A

Example:

Alarm

Alarm Recording C

Alarm Recording B

<ALARM OPERATION SET>
ALARM RETRIGGER : ON

MAIN MON. DISPLAY : NC
ALARM PRIORITY : LAST
MON.2 DISPLAY : OFF

e07_l8hbg_us_7.fm Page 84 Thursday, November 25, 2004 3:02 PM