Sanyo DSR-3709 User Manual

Page 97

Advertising
background image

GENERAL SET

4

96

English

SE
TTIN

GS

4

Following this, turn the shuttle dial
clockwise.

5

Where necessary, use the same
procedure to set the “ID2” and “ID3”
passwords.

6

When setting has been completed,
press the [EXIT/OSD] button.

The setting procedure is ended and the display returns to
the normal screen.

Use the following procedure to make RS-485 settings.
Connect the digital video recorder's RS-485 (A, B) control
terminals on the rear panel to the system controller or
similar device.

1

Press the [MENU] button and turn the
jog dial to select “3. GENERAL SET”,
and then turn the shuttle dial clockwise.

The <GENERAL SET> screen appears.

2

Turn the jog dial to select “6. RS-485
SET”, and then turn the shuttle dial
clockwise.

The <RS-485 SET> screen is displayed with the cursor
positioned on “DATA SPEED”.

3

Turn the shuttle dial clockwise and turn
the jog dial to set “DATA SPEED”, and
then turn the shuttle dial clockwise.

The cursor moves to “STATUS INFO”.

[Settings] (‹ indicates default setting)

4

Turn the shuttle dial clockwise and turn
the jog dial to set “STATUS INFO”, and
then turn the shuttle dial clockwise.

The cursor moves to “ALARM INFO”.

[Settings] (‹ indicates default setting)

Setting RS-485

<NETWORK SET>
NETWORK CONTROL : ON(NETWORK)
NETWORK STATUS : ON
IP ADDRESS : 192.168. 0. 1
SUBNET MASK : 255.255.255. 0
GATEWAY : 0. 0. 0. 0
PORT : 00080
ID : PASSWORD (4-8)
ID1 : AB123456
ID2 : 2222----
ID3 : 3333----

EXIT/OSD

<GENERAL SET>
1.DISPLAY SET ->
2.BUZZER SET ->
3.SECURITY LOCK SET ->
4.HDD SET ->
5.NETWORK SET ->
6.RS-485 SET ->
7.CAMERA CONTROL SET ->

MOVE:JOG SELECT:SHUTTLE

MENU

Setting

Description

DATA
SPEED

2400, 4800, 9600, ‹19200

Setting

Description

‹

ON

Status information is transmitted.

OFF

Status information is not transmitted.

<RS-485 SET>

DATA SPEED : 19200
STATUS INFO : ON
ALARM INFO : ON
ADDRESS : 001

<RS-485 SET>

DATA SPEED : 19200
STATUS INFO : ON
ALARM INFO : ON
ADDRESS : 000

<RS-485 SET>

DATA SPEED : 19200
STATUS INFO : ON
ALARM INFO : ON
ADDRESS : 000

e00_l8hbg_us_7.book Page 96 Thursday, November 25, 2004 1:44 PM