Sanyo DSR-3709 User Manual

Page 69

Advertising
background image

RECORD SET

3

68

English

SE
TTIN

GS

2

Turn the jog dial to select setting (OFF,
for example), and then turn the shuttle
dial clockwise.

“REMAINING DISK WARNING” changes to “1%” from “**”.

[Settings] (‹ indicates default setting)

.

z

If this is set to “OFF”, the FULL indicator or ALARM
FULL indicator will start to flash when the remaining
hard-disk capacity reaches the percentage set for
“REMAINING DISK WARNING”.

3

Use the same procedure to set “ALARM
RECORDING AREA” to “OFF”.

4

Turn the jog dial to select “REMAINING
DISK WARNING”, and then turn the
shuttle dial clockwise.

5

Turn the jog dial to set the remaining
capacity, and then turn the shuttle dial
clockwise.

The remaining capacity can be set anywhere between 1%
(default) and 10%.

6

Press the [EXIT/OSD] button.

The setting procedure is ended and the display returns to
the normal screen.

Turn “OVERWRITE” to “OFF” to display the remaining
memory for the current recording area on the operating
display.
Also, if remaining memory reaches the set percentage, the
FULL indictor flashes for normal recording area and the
ALARM FULL indicator flashes for the alarm recording
area. When the remaining memory runs out, the indicator
switches to a permanently lit condition and recording stops
automatically.

Make a new “AREA FULL RESET” setting for “NORMAL
RECORDING AREA” and “ALARM RECORDING AREA”
on the <RECORDING AREA SET> screen. (JP.66)

Setting

Description

OFF

Recording is stopped when the normal recording area
becomes full.

‹

ON

Overwriting automatically starts from the beginning of
the normal recording area when it becomes full.

<RECORDING CONDITIONS SET>
NORMAL RECORDING AREA
OVERWRITE : OFF
ALARM RECORDING AREA
OVERWRITE : ON

REMAINING DISK WARNING : 1 %
SERIES REC : OFF
AUTO DELETE : OFF

Remaining disk

warning

<RECORDING CONDITIONS SET>
NORMAL RECORDING AREA
OVERWRITE : OFF
ALARM RECORDING AREA
OVERWRITE : OFF

REMAINING DISK WARNING : 1 %
SERIES REC : OFF
AUTO DELETE : OFF

When the normal recording area or the alarm
recording area become full

EXIT/OSD

01-01-04 00:00:00 REC 1% EN A ALARM 0000

02

FULL indicator

ALARM FULL indicator

Remaining

capacity

display

Operation

display area

<RECORDING AREA SET>
TOTAL CAPACITY : 82GB
NORMAL RECORDING AREA : 80 %
AREA FULL RESET ->
ALARM RECORDING AREA : 19 %
AREA FULL RESET ->
ARCHIVE AREA : 1 %
AREA FULL RESET ->

CAUTION : WHEN THE AREA SETTING IS CHANGED,
THE WHOLE AREA WILL BE INITIALIZED !

e00_l8hbg_us_7.book Page 68 Thursday, November 25, 2004 1:44 PM