Hardware [sensor] function, Description – Samsung SPR-7416 User Manual

Page 19

Advertising
background image

Hardware [Sensor]

Function

• Record camera image when the external sensor signal is triggered.

• Beep when the external sensor detects any signal.

• Activate external control output on receipt of sensor signal.

Description

Select Sensor

: The number of external sensors and input terminal should be correspondent to each other.

NC/NO

: Configure Sensor

Each time when the button is clicked it will change to [NC]<->[NO] and vice versa.

(Default is set to [NC])

NC (Normal Close Type sensor)

: While on detection mode, choose this when sensor is near the point of contact

NO (Normal Open Type sensor)

: While on detection mode, choose this when sensor’s contract point is open.

Alarm

: While on Sensor detection mode, alarm will be on when sensor activates.

If the recording mode is set to “Continuous” beeping will not work.

Recording time by sensor

: When there is a signal from sensor connected to system, this function is to setup time

which will record camera’s image linked with sensor.

(Possible to setup 1sec, 5sec, 10sec, 20sec, 30sec, 1Min, 2Min, 3Min, or Manual mode.

Factory value is set to 1 sec)

3-1

3-1

Environment Setup

Advertising