Chapter 3 menus – SIGMA SQC-122c User Manual

Page 42

Advertising
background image

Chapter 3

Menus

3-9

Each layer consists of a film (i.e. a material), plus the deposition rate and thickness that
are desired for this layer. The Layer Edit Menu provides access to these layer
parameters:

Fnl Thk

Thickness Limit

Start Mode

Ramp 1

Start Thkness

R a m p T i m e

New Rate

Ramp 2

Disabled

99.0

0:10:00

4.500

Enabled

Manual

0.000

9.000

En/Dis

A/s

h : m m : s s

k A

En/Dis

Auto/Man.

A

k A

R A T E ( A / s )

0.0

Edit Layer Menu

Exit to

Main

Prev

M e n u

Edit

T H I C K N E S S ( k A )

0.000

P O W E R ( % )

0.0

My Process 2 -> Layer 2 -> AluminumOxide

P a r a m e t e r

Value

Units

Init Rate

9.9

A/s

Time Setpoint

0:00:00

h : m m : s s

Exit to Main

Returns to the Main Menu.

Prev Menu

Returns to the Layer Select Menu.

Edit

Selects the highlighted parameter for edit. SoftKey functions
change to:
Next: Store parameter and move to next for editing.
Cancel: Stop editing and undo changes to selected parameter.
Enter: Stop editing and save values for selected parameter.
Control Knob: Turn to adjust value. Push to store value and
move to next parameter.

Control Knob

Scrolls through the list of layer parameters.

Advertising