Figure223 power supply adapter board leds, Table21 led status indicators, Figure 2-23 – Sun Microsystems 2000E User Manual

Page 41: Power supply adapter board leds, Table 2-1, Led status indicators

Advertising
background image

Power Supply Installation

2-25

2

Figure 2-23 Power Supply Adapter Board LEDs

Table 2-1

LED Status Indicators

Location

LED

Condition

Front panel

Left LED
(green)

On — DC power supply is receiving AC current.
Off — There is no DC power.

Middle LED
(yellow)

On — (first 60 seconds) Self tests are running.
Off — (after self tests end) No hardware failures.
On — (after self tests end) Hardware failure was detected.

Right LED
(green)

Off — (first 60 seconds) Self tests are running.
On — (after self tests end) System is running.
Off — (after self tests end) System cannot run; repair is needed.

All system boards

Lower 8 LEDs

During POST, LEDs cycle on and off in irregular pattern.

Master system board only

Lower 8 LEDs

After POST, LEDs display cyclic pattern.

All slave system boards

Lower 8 LEDs

After POST, LEDs display solid pattern until boot is ended, then LEDs
display same cycling pattern as master board. After boot ends, for boards
without SPARC modules, LEDs continue to display solid pattern. After
boot ends, LEDs on failed boards should be OFF.

Power supply adapter
board (redundant-
capable chassis only)

Left LED

Right LED

On — bottom power supply failed, or the circuit breaker (breaker box)

tripped.

Off — top power supply fail, or the circuit breaker (breaker box) tripped.

Power supply adapter board

Sense cable to bottom power supply

Sense cable to backplane

Sense cable to top power supply

Bottom

Power Supply

Top

Power Supply

LEDs (2 each)