626

TC MODE

Select the time code recording mode.
i-prs (int preset): Set an initial value, then record the output of the

internal time code generator.

i-reg (int regen): Record the output of the internal time code generator,

initialized to time code following continuously upon the time code of
the last frame of the last clip on the disc. When clips files are written
or transferred via a FAM or FTP connection, the time code of the clip
is recorded so that it is continuous with the time code of the last
frame of the last clip on the disc.

e-reg (ext regen): Record the output of the internal time code generator,

synchronized to an external time code generator.

r-reg (rp188 regen): Record the output of the internal time code

generator, synchronized to SMPTE RP188 LTC in an SDI signal.

e-prs (ext preset): Directly record the input of an external time code

generator.

See 4-1-2 “Recording Time Code and User Bit Values” (page 43) for
more information about time code recording modes.

627

RUN MODE

When item 626 is set to “int preset,” select the run mode of the internal
time code generator.
free (free run): Time code advances continually.
rec (rec run): Time code advances only during recording.

628

DF MODE

In 525(U)/525(J) line modes, when item 626 is set to “int preset,” select
the frame mode of the internal time code generator and counter.
df (on (df)): Drop-frame mode
ndf (off (ndf)): Non-drop frame mode

629

TC SELECT

Select the type of time data to show in the time data display, and the type
of external time code when item 626 is set to “ext regen.”
vitc: Display time code as VITC, or select VITC as the external time

code.

tc: Display time code as TC, or select TC as the external time code.

See 4-1-2 “Recording Time Code and User Bit Values” (page 43) for
more information about selecting external time code.

651

UMID SDI OUTPUT

Select whether to output UMID in the VANC of the SDI output.
off: Do not output.
on: Output.

See 8-3-3 “Using UMID Data” (page 111) for more information about
UMID.

652

UMID SDI VANC LINE

Select the line in which UMID is output when menu item 651 is set to “on.”
12 H (12 line), 13 H (13 line), 15 H (15 line), 16 H (16 line), 17 H (17

line), 18 H (18 line), 19 H (19 line) (525(U)/525(J) line modes)

9 H (9 line), 10 H (10 line), 12 H (12 line), 13 H (13 line), 14 H (14 line),

15 H (15 line), 16 H (16 line), 17 H (17 line), 18 H (18 line) (625 line
mode)

See 8-3-3 “Using UMID Data” (page 111) for more information about
UMID.

657

ESSENCE MARK SDI OUTPUT

Select whether to output essence marks in the SDI output VANC.

off: Do not output.
on: Output.

660

ESSENCE MARK SDI VANC LINE

When item 657 is set to “on,” select the line to which to output essence

marks.
12 H (12 line), 13 H (13 line), 15 H (15 line), 16 H (16 line), 17 H (17

line), 18 H (18 line), 19 H (19 line) (525(U)/525(J) line modes)

9 H (9 line), 10 H (10 line), 12 H (12 line), 13 H (13 line), 14 H (14 line),

15 H (15 line), 16 H (16 line), 17 H (17 line), 18 H (18 line) (625 ine
mode)

Menu items in the 600s, relating to the time code, metadata, and UMID

Item number Item name

Settings