Sony XDCAM PDW-1500 User Manual

Page 127

Advertising
background image

Chap

te

r

9

Maint

e

n

anc

e and

T

roub

les
h

o

o

ting

127

9-3 Alarms

IMX50 Clip
IMX40 Clip
IMX30 Clip
DVCAM Clip
4CHx24 Clip
8CHx16 Clip

on, limit

A recording, E-E display, or edit preset
operation was attempted on a disc
recorded in a format different from the
setting of basic menu item 031
“RECORDING FORMAT.”

To perform these operations on the disc,
change the setting of basic menu item 031.

See 8-2-2 “Basic Menu Operations” (page
95)
about how to change this setting.

REC INHI.!

on, limit

An attempt to save the current clip list
was made while the REC INH indicator
was lit.

To perform these operations, cancel all of
the following write-protect settings.
• Write Inhibit tab of the disc
• Setting of extended menu item 310 “REC

INHIBIT”

• Mismatch between the recorded

sections of the disc and the setting of
basic menu item 031 “RECORDING
FORMAT”

REC INHI.!

on, limit, off

An attempt to delete a clip was made
while the REC INH indicator was lit.

REC INHI.!

on, limit, off

An attempt to format a disc was made
while the REC INH indicator was lit.

No Clip!

on, limit

A playback or search button was
pressed for a disc containing no
recorded clips.

These operations are not possible.

No Clip!

on, limit, off

An attempt was made to delete a clip
from a disc containing no recorded clips.

Disc Top!

on

The PREV button was pressed while
stopped at the top of the disc, or an
attempt was made to perform a high-
speed reverse search.

Disc End!

on

The NEXT button was pressed while
stopped at the end of the disc, or an
attempt was made to perform a high-
speed forward search.

MAX # Files

on, limit, off

The number of files on the disc had
reached the upper limit (5000), or there
was not enough capacity in the General
directory when an attempt was made to
record, display an E-E picture, record an
essence mark, or add a quick scene
selection sub clip.

Insert a different disc with enough free
capacity.

Disc Full!

on, limit, off

An attempt was made to record or
display an E-E picture when there was
not enough free capacity on the disc, or
when the number of recorded clips had
reached the upper limit (300).

MAX# SB CLP

on, limit, off

An attempt was made to add a sub clip
when the number of registered sub clips
had already reached the upper limit
(300) of the specifications of this unit.

These operations are not possible.

CL OVER DUR

on, limit, off

An attempt was made to add a sub clip
when the total duration of sub clips in the
clip list had already reached the upper
limit (24 hours) of the specifications of
this unit.

Run Salvage

on, limit, off

An attempt was made to record, display
an E-E picture, record an essence mark,
or add a quick scene selection sub clip
on a disc which requires clip recovery
(salvage).

Try the operation again after executing the
salvage function.

For details, see 3-5-7 “Handling of Discs
When Recording Does Not End Normally
(Salvage Function)” (page 39).

CNT mode!

on

A time code or user bits preset operation
was attempted with “COUNTER”
selected by the COUNTER SELECT
button.

Try the operation again after selecting “TC”
or “UB” with the COUNTER SELECT
button.

Message in time
data display

Display
condition

a)

Description

Action

Advertising