4.2

Transport and storage conditions

Although the device is of rugged design, its internal components are sensitive to
severe vibrations or shock. You must therefore protect the device against severe
mechanical loads.

You should always use the original packaging for shipping and transporting the
device.

Unpack the device at its final destination.

Do not transport the device when it is mounted.

Observe the notes about temporary storage in Chapter Service and Mainte-
nance
under Battery (Section 11.1).

The following information applies to modules transported and stored in the origi-
nal packaging.

The climatic environmental conditions correspond to IEC 60721-3-2, Class 2K4
for transport

The mechanical environmental conditions correspond to IEC 60721-3-2, Class
2M2 for transport

Caution

Risk of damage to the device!

If you are transporting the device in cold weather with large fluctuations in tem-
perature, care must be taken to ensure that no moisture forms on or in the device
(condensation).

If condensation has developed, wait at least 12 hours before you switch on the
device.

Caution

Observe these conditions each time the device is transported, otherwise the guar-
antee is void.

Table 4-1

Transport and storage conditions

Type of condition

Permissible range

Free fall (in transport packaging)

<= 1 m

Temperature

-40° C to +70° C

Atmospheric pressure

1080 to 660 hPa (corresponds to an altitude
of

-1000 to 3500 m)

Maximum temperature change

20° C/h

Relative humidity

10 to 95% (at 25° C without condensation)