4 connecting the time receivers, 1 point-to-point connections via output 1 to 3, Connecting the time receivers – Siemens SICLOCK TC 400 User Manual

Page 43: Point-to-point connections via output 1 to 3, 77< dfwlyh

Advertising
background image

Connecting

6-41

© Siemens AG 2007 All Rights Reserved
SICLOCK

®

TC 400

6.4

Connecting the time receivers

Time receivers can be connected via point-to-point connections (OUTPUT 1 to 3)
or via Ethernet.

Four Ethernet ports are available for the Ethernet connection and can be param-
eterized accordingly.

A redundant point-to-point connection can be implemented via OUTPUTs 1 and
2 when two SICLOCK TC 400s are used.

6.4.1

Point-to-point connections via OUTPUT 1 to 3

Current signal – low-resistance receiver (e.g. optocoupler)

Point-to-point connections via an active current interface can be connected to
OUTPUTs 1 and 2 as shown in Fig. 6-6.

Figure 6-6 OUTPUTs 1 and 2 as current interface

Table 6-3

Terminals of OUTPUTs 1 and 2

Terminal

Designation

1

OUTPUT 1 GND

2

OUTPUT 1

3

OUTPUT 2

4

OUTPUT 2 GND

2

1

24 V / 20 mA

3

4