background image

Chapter 5: Advanced Serverboard Setup

5-13

Overheat/Fan Fail LED

Connect an LED to the OH/Fan Fail

connection on pins 7 and 8 of JF1 to

provide warning of system overheat-

ing or system fan failure. The LED

will fl ash/stay on as long as the fan

fail/overheat condition exists. Refer to

the table on the right for pin defi nitions

and Chapter 3 for details.

NIC1/2 LEDs

The NIC (Network Interface Control-

ler) LED connections for JLAN1 are

located on pins 11 and 12 of JF1 and

the NIC LED connections for JLAN2

are located on pins 9 and 10 of JF1.

Attach the NIC cables to display net-

work activity. Refer to the table on the

right for pin defi nitions.

HDD LED

The HDD LED (for IDE and SATA

drives) connection is located on pins

13 and 14 of JF1. Attach the drive

LED cable to these pins to display disk

activity. See the table on the right for

pin defi nitions.

Power Fail LED

The Power Fail LED connection is

located on pins 5 and 6 of JF1. Re-

fer to the table on the right for pin

defi nitions.

HDD LED

Pin Defi nitions (JF1)

Pin# Defi nition

13

Vcc

14

HD Active

NIC1/2 LED

Pin Defi nitions (JF1)

Pin# Defi nition

9/11

Vcc

10/12

Ground

OH/Fan Fail LED

Pin Defi nitions (JF1)

Pin# Defi nition

7

Vcc

8

Ground

Power Fail LED

Pin Defi nitions (JF1)

Pin# Defi nition

5

Vcc

6

Ground