Sega WaveRunner GP User Manual

Page 59

Advertising
background image

www.seuservice.com

50

(2) ROLL VALVE & ETR CHECK

FIG. 9. 3 f c ROLL VALVE & ETR CHECK Screen

In the VALVE TEST MENU, press the SERVICE Button and bring the arrow to ROLL
VALVE & ETR CHECK.

Press the TEST Button to have the PITCH VALVE TEST screen appear.

Turn the Handlebars to the right, and the Ride is subject to the centering force from the right
only.

Turn the Handlebars to the left, and the Ride is subject to the centering force from the left only.

Position the Handlebars in the center to stop the centering movement.

Gripping the Throttle Lever during áBÅ`áD above increases the air pressure and releasing the
Throttle Lever decreases the air pressure.

During áBÅ`áE, check the functioning of each Air Valve.

Press the TEST Button to return to the VALVE TEST Menu.

Choose EXIT and press the TEST Button to return to the Game Test Menu screen.

TEST PROCEDURE

1

2

3

4

5

6

7

8

9

ROLL VALVE & ETR CHECK

ROLL VALVE

ON

RIGHT VALVE

ON

LEFT VALVE

ON

ROLL ETR

F9H

ROLL VOLUME

80H

PRESS TEST BUTTON TO EXIT

Advertising