58

10 - 1 OVERVIEW OF AIR DRIVE SYSTEM

VALVE

CYLINDER

COMPRESSOR UNIT

TANK UNIT

FILTER

REGULATOR

VALVE

CYLINDER

VALVE

CYLINDER

CIRCUIT PROTECTOR

POWER

DRIVE BOARD

FIG. 10.1 a Air Drive System Schematic

This product uses the compressor. Be sure to turn off the main switch of the AC Unit and start
working after checking that the compressor motor has stopped.

FILTER

VALVE UNIT

REGULATOR

COMPRESSOR

FRONT CYLINDER

REAR CYLINDER

TANK UNIT

COMPRESSOR UNIT / TANK UNIT
Compresses and stores air by causing the AC Motor to turn the Compressor.

FILTER / REGULATOR
Filters foreign matter consisting of fine particles, and water contents in the compression air
(primary side) stored in the COMPRESSOR UNIT and governs the compressed air to a preset
pressure (secondary side). Two Regulators are equipped with: One for high pressure and the
other for low pressure.

CIRCUIT PROTECTOR
Protects the AC motor for the compressor from overcurrent.

DRIVE BOARD (inside the Front Cabinet)
The DRIVE BOARD controls the entire Air Drive System by activating or stopping the
Compressor depending on the pressure inside the Compressor Unit, and by sending a signal to
open/close each valve in accordance with the progress of game play.

FIG. 10.1 b Overview of air drive system