15.3.5

Control of loop formed before fusing section

• The difference between the fusing speed and media conveyance speed is corrected to

prevent double transferred images and brush effects from occurring.

• The Paper Loop Sensor (PC6) detects the length of the loop formed in the media

between the 2nd Transfer Roller and the Fusing Pressure Roller. The fusing speed is
then varied according to the length of the loop detected. By varying the fusing speed, any
effects from the Fusing Pressure Roller side (part-to-part variations, change of parts over
time) are prevented from being transferred to the 2nd transfer section.

• No loop control is provided to perform the fusing process at high speeds when envelopes

are used (to prevent wrinkles).

2-100

• Fusing deceleration (low speed):

When the media loop length is small, the actuator of the Paper Loop Sensor (PC6) is
pushed up a small amount and the sensor is unblocked. When the sensor is unblocked,
the fusing speed is decelerated (-1.36%).

• Fusing acceleration (high speed):

When the media loop length is large, the actuator of the Paper Loop Sensor (PC6) is
pushed up a large amount and the sensor is blocked. When the sensor is blocked, the
fusing speed is accelerated (+1.64%).

4138to2069c1

4138to2069c2

Fusing Pressure
Roller

2nd Transfer Roller

Paper Loop Sensor

Actuator

Fusing deceleration

Fusing acceleration