6 waste toner near-full condition detection, 6 waste toner near-full condition detection -59 – Konica Minolta 5430 DL 5440 DL 5450 User Manual

Page 96

Advertising
background image

Main Unit Theory of Operation

Toner Collecting Section

2-59

II Comp

osition

/O

p

eration

10.3.6

Waste toner near-full condition detection

• A waste toner near-full condition is detected using the output state of the Waste Toner

Full Sensor.

• A waste toner full condition is detected based on the dot count.
• The output value of the Waste Toner Full Sensor cannot be acquired during the AIDC

control (registration correction, gamma correction). During this period, therefore, the fol-
lowing control procedures are not performed: “waste toner status decision,” “waste toner
full condition reset decision,” “waste toner near-full condition reset decision,” and “waste
toner near-full condition detection control.”

A. Waste toner near-full condition detection control
• A waste toner near-full condition is detected when the Waste Toner Full Sensor (PC11)

continuously outputs a voltage of a predetermined value or more for a predetermined
period of time or more.

• At this time, a waste toner near-full condition warning is given on the panel.
• To prevent false detection, a conveying screw is installed in the Waste Toner Box, ensur-

ing that waste toner is uniformly accumulated in the box.

Power source

Full condition

Waste toner /

Status decision

Full condition

detection

Full condition

reset decision

Near-full

condition reset

Near-full

condition

4138to2137e0

4138to2081c0

Waste Toner Full Sensor (PC11)

Box Tray

When the sensor is unblocked

When the sensor is blocked

5430DL_5440DL_5450_TO_PDF.book 59 ページ 2005年4月12日 火曜日 午後4時49分