2 photo conductor post-exposure control, Photo conductor post-exposure control -23 – Konica Minolta 5430 DL 5440 DL 5450 User Manual

Page 60

Advertising
background image

Main Unit Theory of Operation

Toner Cartridge / Photo Conductor

2-23

II Comp

osition

/O

p

eration

5.2.2

Photo Conductor post-exposure control

• The entire surface of the Photo Conductor is exposed to light before the Photo Conductor

stops rotating during the stop sequence or color change sequence (from the color print to
monochrome print) after a print cycle.

• Ozone stagnant in areas near the Charge Corona Unit is adsorbed on the surface of the

Photo Conductor. This reduces sensitivity of the Photo Conductor, causing white bands
to occur in the image.

• To prevent this image failure from occurring, the entire surface of the Photo Conductor is

exposed to light and thus neutralized. This effectively prevents the surface of the Photo
Conductor from absorbing ozone.

• <Execution timing>
1.

The total exposure sequence is started after the last image moves past the exposure
position (to prevent dirt on the background due to a potential difference between the
Photo Conductor and the Developing Unit).

5.2.3

Photo Conductor total exposure control upon recovery

• If the “Photo Conductor post-exposure control” described above is not correctly done, the

entire surface of the Photo Conductor is exposed to light, thereby preventing ozone from
being adsorbed on the surface of the Photo Conductor.

• If the “Photo Conductor post-exposure control” is not performed due to a media misfeed

or malfunction, the entire surface of the Photo Conductor is exposed to light at the same
time that the “2nd Transfer Roller cleaning control” is performed during the recovery pro-
cedure from the media misfeed or malfunction.

2-53

• <Execution timing>
1.

If a media misfeed or malfunction was present when the Power Switch was turned OFF
last time, the “Photo Conductor total exposure control upon recovery” sequence is per-
formed at the same time with the 2nd Transfer Roller cleaning control when the Power
Switch is next turned ON.

2.

The control is executed during the recovery procedure from a media misfeed or mal-
function.

5430DL_5440DL_5450_TO_PDF.book 23 ページ 2005年4月12日 火曜日 午後4時49分