Main Unit Theory of Operation

Miscellaneous

2-123

II Comp

osition

/O

p

eration

18. Miscellaneous

18.1 Fan control

18.1.1

Composition

Key

Name

Function/system

[1]

Fusing Cooling Fan Motor (M11)

• Discharges heat generated from the interior parts

(including the Low Voltage Unit, Fusing Unit, Toner
Cartridges/K, and motor drives) from the machine to
prevent the interior temperature from rising
inordinately.

• Air passageway is formed on top of the Low Voltage

Unit, in the duct inside the Toner Cartridge rail, and
below the print head housing. No air flows through
areas around the Toner Cartridges. This effectively
prevents toner from scattering.

[2]

LV Cooling Fan Motor (M10)

• Discharges heat generated from the interior parts

(including the Low Voltage Unit, intermediate transfer
belt section, Toner Cartridges/C, M, Y, and motor
drives) from the machine to prevent the interior tem-
perature from rising inordinately.

[3]

Ozone Ventilation Fan Motor (M12)

• Discharges heat generated from the print head from

the machine to prevent the print head temperature
from becoming inordinately high.

• Removes ozone produced from the Toner Cartridges

and charging section.

• Air passageway is formed on top of the Low Voltage

Unit, in the duct inside the Toner Cartridge rail, and
below the print head housing. No air flows through
areas around the Toner Cartridges. This effectively
prevents toner from scattering.

4138to2111c0

4138to2110c0

[2]

[1]

[3]

[1], [2]

[3]

5430DL_5440DL_5450_TO_PDF.book 123 ページ 2005年4月12日 火曜日 午後4時49分