3 laser emission timing, 4 laser emission area, Laser emission timing -5 – Konica Minolta 5430 DL 5440 DL 5450 User Manual

Page 42: Laser emission area -5

Advertising
background image

Main Unit Theory of Operation

Print Head (PH)

2-5

II Comp

osition

/O

p

eration

2.2.3

Laser emission timing

• When a Ready signal is detected after the lapse of a given period of time after the print

cycle has been started, a Laser ON signal is output from the Print Control Board (PWB-
P).

• The Laser ON signal triggers the firing of each laser light, which illuminates the SOS

Board via the Polygon Mirror, G1 Lens, Separation Mirror (K), and SOS Lens. This gen-
erates an SOS signal.

• This SOS (Start of Scan) signal unifies the timing at which the laser lights are irradiated

for each main scan line.

• The SOS signal is generated only from the K laser light. For the other colors, the emis-

sion timing is determined with reference to K.

2.2.4

Laser emission area

A. Main scan direction (FD)
• The print start position in the FD direction is determined by the FD Print Start signal

(HSYNC) that is output from the Print Control Board (PWB-P) and the width of the
media.

• The laser emission area is determined by the media size.

B. Sub scan direction (CD)
• The print start position in the CD direction is determined by the CD Print Start signal

(TOD) that is output from the Print Control Board (PWB-P) and the length of the media.
However, there is a 4 mm/0.157" wide void area on both edges of the media.

• The laser emission area is determined by the media size. However, there is a 4 mm/

0.157" wide void area on both the leading and trailing edges of the media.

4138to2595c0

Void width: 4 mm/0.157"

Void width: 4 mm/
0.157"

Void width: 4 mm/0.157"

Void width: 4 mm/
0.157"

5430DL_5440DL_5450_TO_PDF.book 5 ページ 2005年4月12日 火曜日 午後4時49分

Advertising