Main Unit Theory of Operation

Fusing Section

2-105

II Comp

osition

/O

p

eration

16.3.4

Fusing temperature control management

• The appropriate type of temperature control is provided according to the machine status.

A. Conditions enabling shift to warm-up control
• The Power Switch is turned ON.
• A malfunction or media misfeed is reset.
• The machine leaves the Power Save mode.
• A door is closed.

B. Condition enabling shift to post-warm-up control
• At the end of the warm-up control (no print request)

C. Conditions enabling shift to wait control
• At the end of the warm-up control (no print request)
• At the end of the post-print cycle control

D. Condition enabling shift to print control
• A print request is accepted.

E. Condition enabling shift to post-print cycle control
• At the end of the print control

F.

Condition enabling shift to heater OFF control

• A malfunction or media misfeed occurs.
• A Power Save mode signal is received.

Reset

4138to2138e0

Warm-up control

Heater OFF

Post-warm-up control

Wait control

Print control

Post-print cycle control