77

Kirby Morgan 37 & 57

© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001

and rotate the stem all the way out, then back again.

The rotation must be smooth. If “hard spots” or un-

evenness are felt during the rotation, the stem may

be bent and could need replacement.

8) Tighten the packing nut with a torque wrench until

moderate resistance is felt when turning the knob.

Torque to 50 inch pounds after seating.

9) Place the spring, and locknut onto the stem secur-

ing the knob.

10) Tighten the locknut until its top is flush with the

top of the knob. The assembly is now complete and

ready for testing.

NOTE: If the valve was removed from the side block

testing of the emergency gas valve is easily accom-

plished by attaching the valve, by itself in the shut

position, on to the bail-out whip from the first stage.

Pressurized to a minimum 135 p.s.i.g. (9.3 bar) us-

ing the EGS Cylinder and dropping it into a bucket

of clean water a minimum 30 seconds to check for

leaks.

11) Before wrapping the threads with pipe tape, check

the fit of the valve assembly pipe threads to the mating

threads of the side block. There should be 2 turns of

hand make up before needing to use a wrench.

A leaking Emergency Gas Valve assembly

can cause the diver to exhaust his entire

EGS (bailout) without his knowledge. This

may lead the diver to mistakenly assume

his EGS supply is available when it is

not. This could lead to panic or drowning

in an emergency. Any worn or damaged

components must be replaced.

A submersible pressure gauge

should always be used with the EGS sys-

tem to help minimize this risk.

WARNING

the first thread. Apply the tape with slight tension to

allow the tape to fill into the threads.

Hand tighten the valve, then continue an additional 1-1/2

to 2 turns with a wrench keeping in mind the proper

alignment of the control knob to the side block. Also,

there should be at least one male thread visible. Check

to be certain the valve is tight by trying to loosen the

fit by hand.

DO NOT TIGHTEN THE VALVE BODY TIGHTER

THAN NECESSARY! OVER TIGHTENING MAY

OVERSTRESS THE PART AND CAUSE THE PART

TO FAIL.

It is NOT necessary to have the control knob for the

emergency gas supply valve perfectly “square,” i.e., at

a 90 degree angle to the side block. Any angle is ac-

ceptable provided that 1) the valve handle can be turned

easily and 2) the diver can locate the handle easily.

7.5.4 Leak Testing the EGS Valve

a) Attach supply whip from the EGS first stage to EGS

helmet valve.

b) Ensure the defogger valve knob is open and the EGS

Valve is shut.

c) Pressurize EGS Valve to a minimum of 135 p.s.i.g.

(9.3 bar) using the EGS cylinder as supply. Allow sys-

tem pressure to stabilize, and then shut the EGS supply

cylinder valve. Note time and final stabilized system

pressure.

d) Perform the leak check for minimum of five min-

utes, using the mild soapy solution, per Chapter 6.

Ensure there is no gas flowing or pressure drop in the

system. There should be no visible signs of external

leakage if the valve is operating properly.

The control knob for the emergency

valve and the defogger knob are not in-

terchangeable. Use only the correct knob

for the appropriate valve.

WARNING

Use only thin Teflon tape when installing

the Emergency Gas Supply valve in the

side block. Thick tape can lead to thread

damage, which may make it impossible

to install the EGS valve in the side block

properly. This could lead to a loss of

breathing gas.

WARNING

If there is less make up, then the threads will need to be

chased with a 1/4” NPT tap to obtain the proper make

up. If thread chasing is required, the bent tube assembly,

the one way valve assembly and steady flow components

must all be removed and the side block body must be

thoroughly cleaned to remove any loose particles.

12) Before installing the valve assembly, wrap the pipe

threads with 1-1/2 turns of Teflon tape starting after

Advertising