Kirby Morgan 37 User Manual

Page 40

Advertising
background image

107

Kirby Morgan 37 & 57

© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001

tube. The square opening on the main tube must be

exposed.

19) Spread the arms of the lever just enough to install

it on the main tube.

Close-up detail of the inlet valve.

20) Study the features of the inlet valve assembly.

There are 4 “wings” towards one end of the assembly

and a bore that creates the balance chamber on the

opposite end.

The wings that align with the lever arm are the 2

that have an additional wall for the lever arm to bear

on. The valve assembly should be inserted into the

main tube with these walls toward the bottom of the

regulator tube.

21) Using a clean wooden dowel rod, that has been

sharpened in a pencil sharpener and inserted in the

open end of the inlet valve, properly align and insert

the inlet valve into the main tube. If this is done

properly, the lever should lift up. If it does not, the

valve has not been inserted correctly.

22) While holding the inlet valve in position, pull

each arm of the lever outward just slightly until the

inlet valves moves further into the main tube, ap-

proximately 1/4 inch. The dowel rod should move in

a bit further to indicate that this has happened.

23) Release your pressure on the dowel rod. The lever

should fall back to its normal position against the

main tube. Push in gently on the dowel and the lever

Inserting the inlet valve into the main tube.

should rise again to approximately a 45 degree angle.

If this does not happen, or the angle is very low, the

inlet valve will need to be removed and reinstalled

to achieve the correct orientation.

24) Remove the dowel rod and insert the spring and

balance spacer with o-ring into the main tube. Make

sure the balance spacer is properly aligned inside the

main tube by pushing in on the end of the space to

see that it move inward (i.e., it engages the hole in

the inlet valve).

25) Thread the flex knob assembly onto the end of

the main tube (closest to the lever arms) until it just

stops. Hand tighten the assembly and then back the

assembly out one turn.

Insert the balance spacer and spring in the main

tube. When it is properly installed the spacer will

engage the inlet valve.

Thread the adjustment knob onto the main tube.

Thread the adjustment nipple into the main tube.

Advertising