75

Kirby Morgan 37 & 57

© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001

Remove the valve stem.

Remove the lock nut, spring and knob.

Undo the packing nut.

7.5 Emergency Valve Assembly

The Emergency valve control knob is not interchange-

able with the defogger valve control knob.

7.5.2 Cleaning and Lubricating

1) Clean all the metal parts in a soap and water solu-

tion, followed by cleaning with a 50/50 dilute solution

of white vinegar/water. Rinse with fresh water. Clean

all parts. See the cleaning instructions in Chapter 6.

2) Inspect the packing and washer for wear and re-

place if necessary. Normally the packing will last a

very long time and does not require replacement as

long as the valve operates smoothly and does not leak.

To replace the packing place the packing nut in a vise

and carefully work the packing out with a small screw

driver, taking care not to damage the threads of the

packing nut. Replace the washer if needed.

3) Inspect the stem seat for unevenness or wear and

replace if necessary. It must also be replaced if the

stem is bent. Damage will include damaged threads,

rounded flats that engage the control knob. Also

inspect the shaft to ensure the conical seat surface is

smooth and free of corrosion or damage.

Inspect the packing and washer.

4) Check the seat in the emergency valve body for

wear or unevenness, galling and corrosion. Check

the seat on the emergency valve stem. To clean up the

seat surface use a pencil eraser to buff the surface.

Inspect all threaded surfaces for damage. Replace the

emergency valve body if any damage is found.

7.5.1 Disassembly of the Emergency Valve

Tools Required:

11/16 inch Open End Wrench

1 inch Open-end Wrench

Torque Wrench Attachments & Torque Wrench

3/8 inch Slotted Flat Blade Screwdriver

Soft Jaw Vice

Lubricant

Teflon Tape

1) Remove the lock nut, spring, and knob.

2) Undo the packing nut, and remove the packing,

and washer.

3) When the packing nut is free of the threads of the

emergency valve body, back out the stem until it is

free of the emergency valve body.

The control knob for the emergency

valve and the defogger knob are not in-

terchangeable. Use only the correct knob

for the appropriate valve.

WARNING