When you pull the flex knob assembly out, the main

tube and related parts will follow.

Separate the flex knob assembly from the main

tube.

11) Slide the balance spacer, spring, inlet valve as-

sembly out from the main tube.

12) Unscrew the adjustment nipple (turn it “out”)

from the main tube. This may require lightly tapping

on the tube to dislodge the parts.

13) Inspect all parts for signs of wear or damage and

replace if necessary.

14) Clean all parts per chapter 6. Lubricate o-rings

and moving parts with a light coating of Christo-

Lube®. It is not necessary to disassemble the flex

knob assembly unless the knob is not working prop-

erly. If this is required, refer to Section

15) Install the o-ring on the adjustment nipple if you

have not already done so. Be sure that the o-ring has

been properly lubricated with Christolube.

16) Install the o-ring on the main tube.

17) Install the o-ring on the balance spacer.

18) Install the bearing clip on the outside of the main

tube. Note that there is a locating pin on the clip that

must engage the correct hole on the main tube.

The clip is correctly positioned when it is on the side

opposite of the depression for the lever on the main

Remove the o-ring from the flex knob packing nut.

You can use a credit card, toothpick, or any soft

device that will not damage the o-ring or the nut.

Remove the balance spacer, spring, inlet valve and

seat from the main tube.

Correct position of bearing clip on main tube.

Bearing clip

Lever depression