Kirby Morgan 37 User Manual

Page 44

Advertising
background image

111

Kirby Morgan 37 & 57

© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001

Main tube

Lever

o-ring

o-ring

o-ring

Balance

spacer

Spring

Seat

Inlet valve

Adjustment nipple

Bearing

clip

8) Remove the adjustment shaft from the flex knob.

With the shaft out, grab the packing nut with one

hand and the flex knob with the other and bend.

There is a boss on the knob that will pop loose from

the packing nut.

9) Remove the o-rings from the adjustment shaft and

packing nut.

10) Remove the lever by gently pulling one leg out

from the slot on the main tube, followed by the sec-

ond leg.

9) Remove the bearing clip from the main tube.

10) Slide the balance spacer, spring, inlet valve as-

sembly out from the main tube.

11) Unscrew the adjustment nipple from the main

tube.

12) Remove the o-ring from the balance spacer.

13) Remove the o-ring from the main tube.

14) Unscrew the adjustment nipple from inside the

main tube and remove the o-ring from the nipple.

15) Remove the retainer ring from the regulator

body.

16) Remove the exhaust valve insert from the regu-

lator body and separate the exhaust valve from the

insert.

17) Inspect all parts for signs of wear or damage and

replace if necessary.

18) Clean all parts per chapter 6. Lubricate o-rings

and moving parts with a light coating of Christo-

Lube®.

Details of the SuperFlow 450 main tube and

associated parts.

Advertising