7.7.10 Tuning the SuperFlow 350 Regulator

1) Remove the clamp, cover and diaphragm.

2) Screw the adjustment knob (clockwise) all the way

in, towards the regulator body.

3) Pressurize the regulator to between 120-150 p.s.i.g.

of supply pressure.

4) Screw the adjustment knob out (counterclockwise)

until the regulator starts to free flow, then screw the

adjustment knob in (clockwise) until the free-flow

just stops. Depress the lever several times to ensure

the free-flow has stopped.

If the free flow does not stop, the adjustment nut is

too tight. If the roller lever is sloppy (loose) the ad-

justment nut is too loose.

5) Insert the inlet valve holding tool into the balance

hole on the inlet tube. Push forward on the tool to

stop the inlet valve stem from turning. Adjust the

nut until there is 1/16 inch (1.5 mm) to 1/8 inch (3.0

mm) of free play at the end of the lever.

Insert the inlet valve holding tool into the balance

hole on the inlet tube.

6) Remove the inlet valve holder tool.

7) Put the diaphragm and cover in place, depressing

the cover tightly to simulate a properly tightened

clamp.

8) Depress the purge button in the center of the

cover.

9) There must be 1/16 inch (1.5 mm) to 1/8 inch (3.0

mm) of free travel before the purge button actuates,

resulting in a slight flow of gas. If a slight flow of gas

develops with the purge button depressed less than

1/16 inch (1.5 mm) the lever will require bending

down.

If the purge button travels further than a 1/8” (3.0

mm) before gas flow starts, the lever will require

bending upward.

NOTE: Before bending the lever, double-check

the adjustments. It is rare that the lever requires

bending. Usually levers only require bending

because of they were improperly serviced previ-

ously, or because of damage during disassembly.

10) To bend the lever up, you’ll need to remove the

lever and carefully place it in a vice. Grip the lever

from the side with a pair of long nosed pliers and

bend the roller end up with your finger. Bend it only

a small amount at a time.

NOTE: Be very careful to not place undue stress

on the lower arms of the lever as this will disfigure

the lower blades and cause spongy operation.

11) To bend the lever down, place the disk end of the

KMDSI 1/4 ” wrench onto the flat area of the adjust-

ment tube within the regulator, sliding the disk as far

as possible under the lever. With your finger, slightly

bend the lever down over the disk to the desired

height. Be careful not to bend the lever too far! Bend

it slightly then check it.

Test the response of the purge button.

Note that the legs of the

lever must be properly

aligned and in the same

plane for the lever to

work correctly.