Kirby Morgan 37 User Manual

Page 36

Advertising
background image

103

Kirby Morgan 37 & 57

© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001

Turn the adjustment nipple 1/16 of a turn at a time

to adjust the performance of the regulator.

7.12.2 Adjusting the SuperFlow 450
Tools required:

Flat blade screwdriver

11/16 inch Open-end Attachment on Torque

Wrench

7/8 inch Open-end Attachment on Torque Wrench

7/8 inch Open-end Wrench

1 inch Open End Wrench

1/4” to 5/16” Dowel Rod sharpened by pencil sharp-

ener

1) Remove the bent tube assembly from the helmet,

per this chapter.

2) Remove the bent tube adapter.

3) Insert a flat head screwdriver into slot in the end

of the adjustment nipple.

Remove the bent tube and the bent tube adapter.

Before you reinstall the bent tube, connect the

low pressure hose to the regulator and pressurize

it again. Push in on the regulator cover 1/4 inch.

The regulator should just begin to free flow if it is

properly adjusted.

5) If the regulator began to free flow too easily,

turn the adjustment nipple IN 1/16 of a turn. Only

small adjustments are needed to tune the regulator.

Reconnect the low pressure hose, pressurize it and

test again.

6) If you are unable to obtain a proper adjustment

with the regulator following this procedure, you will

need to disassemble the regulator to check the condi-

tion of the lever.

7) Once the regulator is properly adjusted, reinstall

the bent tube adapter and o-ring. Tighten the adapter

to 30 inch pounds.

8) Reinstall the bent tube assembly as per Section

this chapter.

4) If the regulator did not free flow when the regulator

cover was pushed in, turn the adjustment nipple OUT

1/16 of a turn. Only small adjustments are needed to

tune the regulator. Reconnect the low pressure hose,

pressurize it and test again.

Advertising