Kirby Morgan 37 User Manual

Page 16

Advertising
background image

83

Kirby Morgan 37 & 57

© Copyright 1970-2008 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 080508001

NOTE: Ensure the adjustment shaft (85) rotates

smoothly.

6) Thread the packing nut onto the regulator body

(81) and tighten with the 3/4” torque wrench to 40

inch pounds after seating, turn the knob all the way

in and all the way out making sure there is no inter-

ference.

7.7.6 SuperFlow 350 Demand Regulator

Removal from Helmet

Tools Required:

Torque Wrench and 1 3/8 inch Socket

1 /4 inch Flat Blade Attachment on Torque Screw-

driver

Torque Wrench and 11/16 Open-end Attachment

Torque Wrench and 13/16 Open-end Attachment

Torque Wrench and 7/8 inch Open-end Attachment

7/8 inch Open-end Wrench

1) To remove the regulator from the helmet, the bent

tube should be disconnected first. The bent tube as-

sembly should be loosened at the side block and dis-

connected from the regulator. It may now be swiveled

out of the way or completely removed.

The regulator mount nut must be removed to

remove the regulator.

2) Remove the whiskers from the port retainer (108)

by removing the screws. Take care not to lose the

spacers or kidney plates.

3) Remove the nose block device per Chapter 8.

4) Remove the oral nasal mask.

5) The regulator mount nut is removed along with the

sealing O-ring.

6) Cut the tie wrap that connects the regulator body

to the Quad Valve cover.

7) Now the regulator assembly can be pulled out of

the helmet.

8) The center section of the exhaust whisker, named

the exhaust main body has a tie wrap holding it in

place. Remove the tie wrap then stretch the body off

the regulator exhaust flange.

9) Older model double or single exhaust whiskers are

removed similarly.

Advertising