7.7.9 Reassembly of the SuperFlow 350

Demand Regulator

NOTE: Use the blow-apart in the back of the

manual to help ensure correct assembly.

1) Install the exhaust flange, gasket, and screws onto

the regulator body. Use Loctite 222 to secure the

screws. Tighten the screws to 6 inch pounds.

2) Trim off any excess material from the gasket that

might interfere with the operation of the exhaust

valve.

3) Install the new exhaust valve into the regulator and

trim off any excess stem that may interfere with the

movement of the lever or inlet valve.

The gasket must be installed between the flange

and regulator body.

Be sure to use Loctite to install the screws in the

regulator body.

The screws that hold the flange on the regulator

body should be tightened to six inch pounds.

If the flange is tightened too much, the gasket

will protrude into the exhaust valve opening and

interfere with proper regulator performance.

The exhaust valve is installed on the outside of the

flange.