Connection Procedure

Issue 1 CRCS R6.0 April 1999 11

Figure 6.

Remote CRCS Connection to MCU (Modem Pooling)

5. Connect the female end of the RS232 cable to the male end of either an

adapter or the CRCS PC first serial port.

6. Connect the male end of the RS232 cable to the female 25-pin RS232 con-

nector on the analog modem (remote connection) or data module (local
connection).

Figure 7.

Connecting the MCU to the CRCS PC

7. If you are using the 8400B data module (TN2224 required), go to step 8. If

you are using the 7400B data module, verify or change the following dip
switch settings:

n

For a standalone data-only 7400B data module, set dip switch #1 to
ON (UP), if no phone is connected. All other dip switches should be
set to the OFF position (DOWN);

n

If you are using a phone on a 7400B data module, set all dip
switches to the OFF position (DOWN).

8. Continue with "Checking the Modem Settings" on page 12.

Public/Private

Network

Modem

PC

7400A

7400A

3800

3800

RS232

Analog

DCP

DCP

DS1

TN754B

TN746B

Analog

Analog

RS232

Voice Grade
Data Call

TDM Bus

MCU

Cross-Connect

at MDF

103A

or Wall

Jack

7400B/8400B

PC

TN754B/

TN2224

B25A

D8W

M25B

5000 Feet